Power Supply:
Max Consumption: Transducers Power Supply: Rejection: CPU: Memory: Display: Status Indicators: Front Buttons: Errors on Display: Accuracy: Stability: Frequency Range: Fequency Resolution: Operating Temperature: Storage Temperature: Humidity: Case: Front Protection: Terminals: Dimensions: Drill Gauge Dimensions: Weight: DIP Switch Settings: Cabling: Compliance:
| S311D-XX-L: 10-40 VDC, 19-28 VAC 50-60 Hz, Max 3W S311D-XX-H: 85-265 VAC 50-60 Hz, Max 3W 3 W Max 17 V 50-60 Hz 8 bit EEPROM data memory 10 years LED 4, 6, 8, 11 (4+7) figures 2 alarm LED on threshold Three buttons for navigation Alarm, burn-out 0.1% 0.01%/K 0.00015 Hz to 10 kHz 0.05% -10 to +65 °C -20 to 85 °C Min 30%, Max 90% not condensing PPO auto extinguish by DIN 43700 IP65 Extraction, step 5 96 x 48 x 98 mm 91 x 45 mm 200 g No Yes, in factory EN 61000-6-4/2002, EN 61000-6-2/2005, EN 61010-1/2001
|