Power Supply: Power Consumption: Galvanic Isolation: Protections: Status Indicators:
Installation Class: Pollution Rating: IP Protection: Operating Temperature: Humidity: Dimensions: Weight: Connections: Mounting: Channels: Accuracy:
DIP Switch:
Standard:
| 10 to 40 VDC, 19 to 28 VAC, 50-60 Hz Max 2.5 W Power Supply, Input, Output (1.5 kVAC) Output/Supply Against Impulse Over Voltage 400 W/ms Power ON on Front Panel Relay Pick-Up Indicator on Front Panel II 2 IP 20 0 to +55 °C 30 - 90 % at +40 °C (non condensing) 17.5 x 100 x 112 mm (W x H x D) 150 g Screw-fit removable terminals for wires up to 2.5 mm² 35 mm DIN 46277 1 Setting Error: 0.2% Temperature Coefficient: 0.02%/°C Linearity Error: 0.05% Input Signal Setup Output Signal Setup (Using a common digital tester) EN50081-2 EN50082-2 EN61010-1
|