Z111 - Frequency to DC Current/Voltage Isolator/Converter
Input: Pulses - Mechanical contact, reed, NPN with 2 and 3 wires, PNP with 3 wires and 24 VDC power supply, Namur, Photoelectric, "HALL" sensor, and variable reluctance Output: Current (0-20, 4-20 mA), Voltage (0-5, 1-5, 0-10, 2-10 VDC)
Power Supply: Channels: Accuracy: Status Indicators:
Galvanic Isolation: Hot Swapping: Power Consumption: Max Frequency: Protections: Protection for Inputs: IP Protection: Humidity: Design: Data Memory: DIP Switch:
19 to 40 VDC, 19 to 28 VAC 1 Input / I Output < 0.3% of Full Scale Power Off Scale Power Supply, Input, Output (1500 VAC) - Digital Yes 2.5 W 9.9 kHz Surges: 400 W/ms. Loop Supply Short-Circuit Protected Except Current: 60V Continuous; Current 200 mA Continuous IP 20 30 - 90 % at +40 °C (non condensing) Terminal Housing for Mounting on 35 mm DIN 46277 EEPROM for all configuration data; storage time: 10 years Inputs Signal Setup Output Signal Setup "V0" self-extinguishing glass filled nylon case 17.5 x 100 x 112 mm (W x H x D) 140 g 0 to +50 °C Plug-in screw clamp terminal blocks, wires up to 2.5 mm² 35 mm DIN 46277 EN50081-2 EN50082-2 EN61010-1 CE, UL-CSA