Power Supply: Max Consumption: Isolation: Input Protection: Supply Protection: Status Indicators:
Installation Class: Pollution Rating: Protection Rating: Operating Temperature: Storage Temperature: Humidity: Dimensions: Weight: Case: Hot Swapping: Connection:
Mounting:
| 10 to 40 VDC or 19 to 28 VAC 0.7 W 1.500 kVAC According Norms in Force 400 W/ms Power Supply Error Data Sending Data Receiving II 2 IP 20 -10 to +65 °C -28 to +85 °C 30 to 90% at +40 C (non condensing) 17.5 x 100 x 112 mm 140 g V0 self-extinguish fiber glass filled Yes Plug-in screw clamp terminal blocks, wires up to 2.5 mm² IDC10 backplane connector for DIN guide RS232 (COM) communication front jack 35 mm DIN 46277
|
|
|
RS485 Interface: RS232 Interface: Protocol: Sample Frequency: Max Distance: Connectivity: Data Store:
| 2 wires, speed rate: 1.2 to 115 kBaud Jack port, baud rate 2.4, data 8 bit, no parity, 1 bit stop ModBUS RTU Slave 10 to 30 Hz 1.200 m Max 32 nodes EEPROM, 40 years
|
|
|
Input Channels: Input Type
Single Wire Resistance: Max Voltage: ADC Resolution: Precision Class: Thermal Drift: Software Configuration: Other Functions: DIP Switch: Standards:
| 4 4 clamp (2, 3, 4 wires ohmeter) Pt100: -200 to +650 °C (f.s. 330 Ω) Pt500: -200 to +750 °C (f.s. 1.800 Ω) Pt1000: -200 to +210 °C (f.s. 1.800 Ω) Ni100: -60 to +250 °C (f.s. 330 Ω) Max 25 Ohm 24 V 14 bit 0.05 25 ppm/K Serial (RS232/485) or Ethernet (Z-NET) parameters setup Yes Communication Parameters EN 61000-6-4/2002, EN 61000-6-2002, EN 61010, EN 60742
|
|
|
|