Power Supply:
Max Consumption: Isolation: Input Protection: Rejection: Status Indicators (LED): Dimensions: Housing, Weight, Color: Operating Temperature: Connection:
Protection Degree: Configuration:
Supported Protocols:
Max CANopen Speed: Standards & Approvals:
| 10 to 40 VDC, 19 to 28 VAC Strain gauge powered by the device 2 W 1.500 kVAC (3 Way) Against ESD up to 4 kV Settable 50 or 60 Hz Power, Communication, Fault 17.5 x 100 x 112 mm PBT, 140 g, black -10 to +65 °C Screw-fit removable for wires up to 3.5 mm IDC10 Back connector for DIN rail frontal Jack RS232 (ModBUS) (COM) connection IP20 DIP switches (baud rate, ID Node) EDS IEC 61131 (setting, stable weight, alarm, threshold, remote wiring) CAN bus standard (2.0 A) CANopen (profile CiA 401 v.2.01) ModBUS RTU (via RS232) 1 Mbps CE, EN 61000-6-4, EN 64000-6-2, EN 61010-1 CAN 2.0A CiA 401 v.2.01 IEC EN 61131-2
|